Features
Random access and direct reading system
New concept and more friendly software
Automatic washing station for both sample and reagent probe
Liquid level detection, collision protection for sample / reagent probe
Reliable cooling system for reagent chamber
8 channels automatic cuvette washing system
Perfect self-checking and alarm function
Bar code reader and ISE Module available on request
Designed with environmental protection concept
Features
Random access and direct reading system
New concept and more friendly software
Automatic washing station for both sample and reagent probe
Liquid level detection, collision protection for sample / reagent probe
Reliable cooling system for reagent chamber
8 channels automatic cuvette washing system
Perfect self-checking and alarm function
Bar code reader and ISE Module available on request
Designed with environmental protection concept
Description: Fully Automated, discrete, random access clinical chemistry analyzer
Measuring principle: Spectrophotometry
Photometric throughput: Up to 250 tests/hours
Photometric system: HCFC rear spectrophotometry
Methodology: End point, Fixed time, Kinetic, Single & Dual Reagent Chemistries
Light source: Mono & Bi chromatic, Linear & non-linear multipoint calibration, Halogen - Tungsten lamp (12V/20W)
Monochromator: Grating Photometry (Holographic Concave Flat Field Grating)
Wavelength: 340 nm, 405 nm, 450 nm, 505 nm, 546 nm, 578 nm, 620 nm, 670 nm
Linear range: 0 ~ 3.3 Abs
Detector: Photodiode array
Reagent tray: 47 positions of Reagents for 24 hours refrigerated compartment, 50 positions for sample
Sample position: Up to 50 positions for sample
Sample cuvette specification: Standard cup, original blood tube, multi-specification tube (10~13) x (75~100 mm)
Sample reagent probe: Digital liquid level detection and vertical collision protection
Sample dilution: Pre & Post dilution facility
Reagent volume: 10~400 µl
Sample volume: 2~50 µl
Dilution vessel: UV plastic semi-permanent cuvette
Reagent bottle volume: 20 & 40 ml
Reaction cuvette: 90 positions, high-quality UV-transmitted plastic cuvette
Reaction volume: 100~400 µl
Reaction temperature: 37±0.1°C
Reaction disk constant temp.: Thermostat air bath
Mixing system: Teflon coated stirrer
Washing system: 8 Channels automatic washing system
PC operation system: Windows 7 or Windows 10
PC configuration: CPU > 2.9 GHz (dual core processor); RAM > 4 GB; Hard disk ≥ 160 GB
Analysis control: Graphical operating software
Report printing: Supports user-defined mode, QC and state information etc.
System connection: RS 232
Calibration method: Linear (One-point, two-point and multi-point), Logit-Log 4P, Logit-Log 5P, Spline, Exponential, Polynomial
Quality control method: Real-time, daily, monthly & QC chart | Visual QC assessment | QC history checking | QC error analysis
Parabola control rules: Westgard multi-rule, L-J chart
Power supply: 100~240 VAC | 50/60Hz | Power 600VA
Ambient temperature: 15°C~25°C
Relative humidity: 40% ~ 85%
Atmospheric pressure: 70~106 kPa
Water consumption: 4L/hour
Dimensions (LxWxH): 744 x 703 x 530 mm
Weight: Approx. 100 kg